TRACING WATER MOVEMENT IN UNSATURATED SOILS AT THE PALO VERDE NUCLEAR POWER
PLANT SITE WEST OF PHOENIX, ARIZONA, U.S.A.
William M. Turner, Ph.D.
INTRODUCTION
The determination of water saturation of oil-bearing rock utilizing neutron logging is
a well-known, down-the-hole geophysical logging technique. Less well known is the
use of neutron logging for the quantitative determination of volumetric soil-moisture
content.
This case study report presents some of the data obtained from a simulated leak in a
lined, wastewater-retention pond at the Palo Verde Nuclear Power Plant site near Buckeye,
Arizona. The wastewater-retention pond is situated on level alluvial terrane.
PROCEDURE
To simulate a leak in a blowdown-water retention pond, AGW scientists constructed an
open-bottomed, steel tank 12 feet (3.7 m) high and 20 feet (6 m) in diameter at the site
of the proposed wastewater-storage pond. We buried the bottom of the tank 5.5 feet
(1.7 m) beneath the land surface and set it in a concrete footing. We constructed
cased, two-inch (5 cm) diameter observation holes, 40-feet (12 m) deep, along four lines
at 90 degrees to each other, radiating away from the tank. In addition, we
constructed an observation hole 120 feet deep in the middle of the tank.
|
Infiltration tank and Water Reservoir.
|
We backfilled the annular space between the PVC casing and the natural soil with dry
bentonite drilling compound to prevent behind-the-pipe, vertical leakage of water.
We filled the tank a depth of seven feet (2 m) with water and allowed it to
infiltrate through the bottom. We maintained a constant head of seven feet (2 m) of
water by automatically adding water to the tank to replace water lost by infiltration and
evaporation.
AGW scientists measured the water level a the small-diameter, make-up water tank daily
to measure volumetric infiltration and evaporation loss. A floating Class A
evaporation pan in the large tank allowed us to measure evaporation loss.
|
Neutron Logging.
|
Prior to filling the tank and at intervals following the filling, which extended over a
six-month period, AGW scientists logged each observation hole with a Troxler soil-moisture
neutron probe. We processed the neutron-probe data provide the following output for
each hole and for each day for which data was acquired.
Volumetric moisture content of the unsaturated zone
Graphical display of the volumetric moisture content with depth
Cumulative change of moisture content from pre-test conditions
Graphical display of the change in volumetric moisture content with depth
From this data, we prepared north-south and east-west cross sections which show the
distribution of soil moisture below and adjacent to the tank resulting from the
infiltration of water from the bottom of the tank.
RESULTS
A sample data set is given in Table 1. The
observation hole for which data is given is located in the center of the tank. From
this data, we calculated the vertical hydraulic conductivity of the earth in the
unsaturated zone was calculated to be 5.0 x 10-6 cm/sec.
We also determined that the area of saturation extended away from the circular tank
about 20 feet (6 m) in all directions. At the end of six months, water had only
penetrated to a depth of about 19 feet (5.8 m) and further advancement of the wetting
front was very slow. We believe that the capillary attraction of the soils
and the negative matric potential ultimately matched
the driving head of water.
CONCLUSION
The use of a neutron probe for quantitatively measuring the movement of water in
unsaturated soils is a rapid and accurate method for evaluating potential seepage
problems. The method is applicable to quantitatively monitoring.
The techniques described here are also applicable to monitoring moisture movement
in:
Tailings dumps
Heap leaching
Land fills
Feedlots
Irrigation projects
Earthen dam embankments
Liquid sludge disposal facilities
Surface-water recharge facilities
Waste-water retention ponds
|